Инструкция по эксплуатации QTECH QFC-P16S4DR-G_v1_CG

Страница 38

Advertising
background image

+7(495) 797-3311
Москва, Новозаводская ул., 18, стр. 1
[email protected]
www.qtech.ru

38

System# write
Are you sure[Y/N]:y
Please wait..Copy OK: 2669 bytes copied
Save current configuration successfully!
System#

3) Конфигурация Ethernet интерфейса номер 1

System#
System# config
Configuration mode, one conmmand input per time. End with CTRL-Z.
System(config)# slot 0
System(config-slot/0)# interface eth 1
System(config-eth/0/1)# autonegotiate
Set successfully

System(config-eth/0/1)# flow-control on
Set successfully

System(config-eth/0/1)# show interface
Interface ID :1
Descr :Slot 0 eth interface 1
Interface type :electrical
Port enable(command) :enable
Port enable status :enable
AutoMdi config :enable
AutoMdi status :enable
Link status :direct
Autonego config :enable
Autonego status :enable
Autonego work status :success
Duplex config :full-duplex
Duplex config status :half-duplex
Duplex status :half-duplex
Speed config :100M
Speed config status :10M
Speed status :10M
Flow control config:on
Flow control status:on
Link :linkdown
MaxFrameLength config :1916
MaxFrameLength status :1916
System(config-eth/0/1)# end

System# write